SA-250 antenna analyzers designed for testing, checking, tuning or repairing antennas and antenna feed lines. (Standing Wave Ratio) and impedance measurement instruments (vector impedance analyzers). Make SURECOM attractive for professionals and hobbyists. It is quite important that graphical display of various parameters over a wide frequency range is a key feature of these analyzers which significantly reduces the time required to adjust an antenna. 2.2 precision LCD screen, High-lumen LCD brightness, easy to read in direct sunlight.
Heavy duty Aluminum enclosure, strong anti-interference ability. Very compact and convenient for field use. Full Band control (No need select Band). Easy setup, only four control buttons with convenient on-screen soft menus.
Constant Battery Status Indicator and Auto Shut-off. Built-in timer shows elapsed time when unit is turned on. High efficiency IC, low power consumption, the longest working hours. More choice measurement frequency. One botton quick scan mode (V1, V2, U) or 3 band by full screen.
Auto marker the Best s. 132-173Mhz / 200-260Mhz / 400-519MHz. 1-1.5V(5 - 10dB). 3.7V 900mah , Li-ion 14500. 0.54MHz/1.35MHz/2.7MHz/5.4MHz/10.8MHz/27MHz/54MHz/108MHz/216MHz/432MHz.
Two-color LED Hidden (when not charging) there are three instructions state: 1, charging (red) ; 2, charging is completed (green) 3, Battery fault (flashing). 70 x 120 x 25 mm. TFT LCD 320 x 240 pixels.Power Source: Built-in 3.7V, 900-mAh , Size 14500 of Lithium battery. Charge Controller: Smart charger, LED charging-status indicator. Voltage Monitor : On-screen DVM, plus battery condition icon. Charger Source: Any USB port, analyzer accepts Micro-USB plug. Power Savers: Auto-off timer, Auto Run/Stop RFgenerator controlInterface.
RF Connector: SMA-female , (optional PL-259 , N connector need adapter). Screen: 2.2 inch high-output color TFT. Function Keys : 4 botton, with on-screen (soft-menu) identifiers.Tuning: Rotary encoder with press-in tuning-step selection. Size: 2.8" wide x 4.0" high x 1.0 deep (7 cm x12cm x 2.5 cm). Weight: 6.1 oz (0.172 kg).
1.0 Turn on and Turn off the power. Turn on the power, Press and hold White botton when the dot disappear from left up angle. Top Menu appeared on the screen.
Turn off the power, You have 2 method. A On Top Menu page , Press and hold the White [F1] botton 5 second. B On Top Menu page , Rotary encoder on "Power off", Press the [F2 Enter]. You can turn the knob select you want function and press F2.
2.0 ANTENNA TEST EXAMPLES (Scan mode). In the Top Menu screen: Rotary encoder on "Scan", Press the [F2 Scan] to frequency mode measurement button, enter Scan (scan mode) screen. 2 scan , button to start the scan operation.
During scanning, in order to ensure measurement accuracy, each frequency will stay for short while. One scanning cycle will take about 1-2 seconds. Once SCAN is done, it will enter "Present" mode (result) screen. You have results on the screen : Show the SWR curve only (because default setting SWR curve only , Zx curve, Rs curve, jx curve Disable).
You can Enable other curve on the screen: On Top Menu page, Rotary encoder on "Zx", Press the [F2 Enter] to enable. Other cure will Disable when Power Off , If want enable in the future, Rotary encoder on "Save", Press the [F2 Enter] to save setting. 2.1 Move the curve marker. View the scan frequency point on the curve on each scan of the specific parameters of the measurement results. View button to start the view operation mode. Rotary encoder , the white triangle curve marker is move. Dot scale will display on screen, Press bottom change the Dot scale, You have 3 options of Dot scale mode for choose, [Dot =x1][Dot =x10][Dot= x25]. SWR Full scale will display on screen, Press bottom change the graphically plot SWR, You have 3 options scale mode for choose, [SWR=x2][SWR= x 0.5][SWR=x1]. 2.2 Quick 1 start Scan mode.Quick view the scan frequency point on the curve on each scan. To start the Quick 1 operation mode. You have 3 options scan mode for choose. 132 to 174 MHz can of the specific parameters of the measurement results. 200 to 260 MHz can of the specific parameters of the measurement results.
400 to 519 MHz can of the specific parameters of the measurement results. 2.3 Quick 2 start Scan mode. Quick view the Full band scan frequency point on the curve on each scan. Press the [Q2] button to start the Quick 2 operation scan mode. Press the [ScanFull] button to start the 3 BAND (132-174,200-260,400-519MHz)Scan operation mode.After you have 2 options. Press the [Scan 2 Mk] button to read the best SWR Yellow triangle curve marker.
Press the [Move Cur] button , Nearby the best SWR Yellow triangle curve marker, Move right hand side. Press again move left hand side. 3.0 ANTENNA TEST EXAMPLES (Single mode). In the Top Menu screen: Rotary encoder on "Single", Press botton "F2" single frequency mode measurement button, enter single (single scan mode) screen. A , Rotary encoder potentiometer enter the center frequency, the specific reference to the above operation "SCAN" sweep measurement mode descriptions.
B , Press the "F2 scan", to start the scan for one time. Single frequency mode provides a single frequency impedance measurement, the measured frequency of the basic parameters are displayed on the screen. To indicate the form of bars and numbers displayed on the screen quickly. The scanning one time , will stop, until you press the F2 Scan button or rotary encoder potentiometer enter the center frequency. In this mode, it can be used as an accurate signal generator, please refer to RF out.
The item "SURECOM SA250 Full Band VHF / UHF Colour Graphic Antenna Analyzer radio ham" is in sale since Tuesday, June 20, 2017. This item is in the category "Consumer Electronics\Radio Communication\Ham, Amateur Radio\Other Ham Radio Equipment". The seller is "diyelecmall108" and is located in ShenZhen ,Guangdong.